{"id":69557,"date":"2019-04-04T14:08:17","date_gmt":"2019-04-04T18:08:17","guid":{"rendered":"http:\/\/www.bumc.bu.edu\/busm\/?page_id=69557"},"modified":"2024-11-05T13:34:43","modified_gmt":"2024-11-05T18:34:43","slug":"other-lab-equipment","status":"publish","type":"page","link":"https:\/\/www.bumc.bu.edu\/camed\/research-impact\/analytical-instrumentation-core\/other-lab-equipment\/","title":{"rendered":"Other Lab Equipment Available Analytical Instrumentation Core"},"content":{"rendered":"<p><a href=\"https:\/\/bostonu.ilab.agilent.com\/account\/login\"><img loading=\"lazy\" width=\"204\" height=\"142\" title=\"Book it now!\" class=\"alignright wp-image-69563 size-full\" alt=\"\" src=\"\/camed\/files\/2019\/04\/SpeedVac1.png\" \/><\/a><\/p>\n<h3><strong>Savant ISS 100 Integrated SpeedVac System<\/strong><\/h3>\n<p>The <a style=\"text-decoration: none;\" href=\"https:\/\/bostonu.ilab.agilent.com\/account\/login\">Savant ISS 100 Integrated SpeedVac System<\/a> is\u00a0compact, fully integrated systems designed specifically for DNA and RNA applications. The DNA-series SpeedVac vacuum concentrator delivers rapid and efficient concentration and drying of DNA\/RNA samples, nucleic acids, PCR preps and synthetic oligos. Our system is designed to accommodate micro centrifuge tubes. A built-in, oil-free PTFE pump produces the vacuum required for rapid drying of samples.<\/p>\n<p><strong>DOM Location:\u00a0<\/strong>650 Albany Street, Rm 830 (X-830)<br \/>\n<strong><br \/>\nInternal Rate (Unassisted): $25 per 2 hours<br \/>\nInternal Rate (Assisted): $55 per 2 hours<br \/>\nExternal Rate (Unassisted): $44.50 per 2 hours<br \/>\nExternal Rate (Assisted): $97.90 per 2 hours<br \/>\n<\/strong><br \/>\n<strong>Instrument Manager<\/strong>: Matthew Au \u2502<a style=\"text-decoration: none;\" href=\"mailto:mau115@bu.edu\">mau115@bu.edu<\/a><a name=\"bioradsupply\"><\/a><\/p>\n<h3><strong>How to Schedule<\/strong><\/h3>\n<p>Please login to<span> <\/span><a style=\"text-decoration: none;\" href=\"https:\/\/bostonu.ilab.agilent.com\/account\/login\">iLab<span>\u00a0<\/span><\/a>system to schedule equipment time or services. For new users please follow the steps outlined in<span> <\/span><a style=\"text-decoration: none;\" href=\"https:\/\/www.bumc.bu.edu\/camed\/research\/cores\/accessing-cores\/information-for-new-users\/\">Information for New Users<\/a>.<\/p>\n<hr \/>\n<p><a href=\"https:\/\/bostonu.ilab.agilent.com\/account\/login\"><img loading=\"lazy\" width=\"300\" height=\"268\" title=\"Book it now!\" class=\"alignright wp-image-89595\" alt=\"\" src=\"\/camed\/files\/2020\/10\/Eppendorf-5430R-Refrigerated-Centrifuge.jpg\" \/><\/a><\/p>\n<h3><strong>Eppendorf 5430R Refrigerated Centrifuge<\/strong><\/h3>\n<p>The\u00a0<a style=\"text-decoration: none;\" href=\"https:\/\/bostonu.ilab.agilent.com\/account\/login\">Eppendorf 5430R Refrigerated Centrifuge <\/a>is equipped with a F-35-6-30 Rotor that is capable of accommodating 15mL and 50mL tubes. It has a maximum speed of 7830 rpm and a temperature range between -11\u00b0C and 40\u00b0C.<\/p>\n<p><strong>DOM Location:\u00a0<\/strong>650 Albany Street, Rm 830 (X-830)<br \/>\n<strong><br \/>\nInternal Rate (Unassisted): $25 per 2 hours<br \/>\nInternal Rate (Assisted): $55 per 2 hours<br \/>\nExternal Rate (Unassisted): $44.50 per 2 hours<br \/>\nExternal Rate (Assisted): $97.90 per 2 hours<br \/>\n<\/strong><br \/>\n<strong>Instrument Manager<\/strong>: Matthew Au\u00a0\u2502<a style=\"text-decoration: none;\" href=\"mailto:mau115@bu.edu\">mau115@bu.edu<\/a><\/p>\n<h3><strong>How to Schedule<\/strong><\/h3>\n<p>Please login to<span> <\/span><a style=\"text-decoration: none;\" href=\"https:\/\/bostonu.ilab.agilent.com\/account\/login\">iLab<span>\u00a0<\/span><\/a>system to schedule equipment time or services. For new users please follow the steps outlined in<span> <\/span><a style=\"text-decoration: none;\" href=\"https:\/\/www.bumc.bu.edu\/camed\/research\/cores\/accessing-cores\/information-for-new-users\/\">Information for New Users<\/a>.<\/p>\n<hr \/>\n<p><a href=\"https:\/\/bostonu.ilab.agilent.com\/account\/login\"><img loading=\"lazy\" src=\"\/camed\/files\/2020\/10\/Eppendorf-Vacufuge-Plus-Concentrator.jpg\" alt=\"\" width=\"300\" height=\"300\" class=\"alignright wp-image-89598 size-full\" title=\"Book it now!\" srcset=\"https:\/\/www.bumc.bu.edu\/camed\/files\/2020\/10\/Eppendorf-Vacufuge-Plus-Concentrator.jpg 300w, https:\/\/www.bumc.bu.edu\/camed\/files\/2020\/10\/Eppendorf-Vacufuge-Plus-Concentrator-150x150.jpg 150w, https:\/\/www.bumc.bu.edu\/camed\/files\/2020\/10\/Eppendorf-Vacufuge-Plus-Concentrator-100x100.jpg 100w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<h3><strong>Eppendorf Vacufuge Plus Concentrator<\/strong><\/h3>\n<p>The\u00a0<a style=\"text-decoration: none;\" href=\"https:\/\/bostonu.ilab.agilent.com\/account\/login\">Eppendorf Vacufuge Plus Concentrator <\/a>provides quick, efficient and gentle vacuum concentration of DNA\/RNA, nucleotides, proteins and other liquid or wet samples in micro centrifuge tubes. It allows you to choose from between three solvent modes, and temperature preselection of room temperature, 30\u00b0C, 45\u00b0C, and 60\u00b0C.<\/p>\n<p><strong>DOM Location:\u00a0<\/strong>650 Albany Street, Rm 830 (X-830)<br \/>\n<strong><br \/>\nInternal Rate (Unassisted): $25 per 2 hours<br \/>\nInternal Rate (Assisted): $55 per 2 hours<br \/>\nExternal Rate (Unassisted): $44.50 per 2 hours<br \/>\nExternal Rate (Assisted): $97.90 per 2 hours<br \/>\n<\/strong><br \/>\n<strong>Instrument Manager<\/strong>: Matthew Au\u00a0\u2502<a style=\"text-decoration: none;\" href=\"mailto:mau115@bu.edu\">mau115@bu.edu<\/a><\/p>\n<h3><strong>How to Schedule<\/strong><\/h3>\n<p>Please login to<span> <\/span><a style=\"text-decoration: none;\" href=\"https:\/\/bostonu.ilab.agilent.com\/account\/login\">iLab<span>\u00a0<\/span><\/a>system to schedule equipment time or services. For new users please follow the steps outlined in<span> <\/span><a style=\"text-decoration: none;\" href=\"https:\/\/www.bumc.bu.edu\/camed\/research\/cores\/accessing-cores\/information-for-new-users\/\">Information for New Users<\/a>.<\/p>\n<hr \/>\n<h3><strong>Labconco FreeZone 2.5 Plus Lyophilizer<\/strong><\/h3>\n<p><a href=\"https:\/\/bostonu.ilab.agilent.com\/account\/login\"><img loading=\"lazy\" src=\"\/camed\/files\/2020\/10\/Labconco-FreeZone-2.5-Plus-Lyophilizer.jpg\" alt=\"\" width=\"189\" height=\"266\" class=\"alignright wp-image-89601 size-full\" title=\"Book it now!\" \/><\/a><br \/>\nThe <a style=\"text-decoration: none;\" href=\"https:\/\/bostonu.ilab.agilent.com\/account\/login\">Labconco FreeZone 2.5 Plus Freeze Dry System<\/a> is suitable for the dehydration of substances and samples that are heat sensitive. Our system is designed for light aqueous sample loads. Therefore, it is not suitable for use with samples containing acetonitrile. Overall, it is capable of removing ~2L of water in a 24-hour period.<\/p>\n<p><strong>DOM Location<\/strong>: 650 Albany Street, Rm 830 (X-830)<\/p>\n<p><strong>Internal Rate (Unassisted): $25 per 2 hours<\/strong><br \/>\n<strong>Internal Rate (Assisted): $55 per 2 hours<\/strong><br \/>\n<strong>External Rate (Unassisted): $44.50 per 2 hours<\/strong><br \/>\n<strong>External Rate (Assisted): $97.90 per 2 hours<\/strong><\/p>\n<p><strong>Instrument Manager<\/strong>: Matthew Au\u00a0\u2502<a style=\"text-decoration: none;\" href=\"mailto:mau115@bu.edu\">mau115@bu.edu<\/a><\/p>\n<h3><strong>How to Schedule<\/strong><\/h3>\n<p>Please login to<span> <\/span><a style=\"text-decoration: none;\" href=\"https:\/\/bostonu.ilab.agilent.com\/account\/login\">iLab<span>\u00a0<\/span><\/a>system to schedule equipment time or services. For new users please follow the steps outlined in<span> <\/span><a style=\"text-decoration: none;\" href=\"https:\/\/www.bumc.bu.edu\/camed\/research\/cores\/accessing-cores\/information-for-new-users\/\">Information for New Users<\/a>.<\/p>\n<p>We also have other basic lab equipment such as an evaporator and sonicator. When scheduling to use any of these instruments, please specify the equipment you are going to use. Alternatively, you can write an email to Matthew Au at <a style=\"text-decoration: none;\" href=\"mailto:mau115@bu.edu\">mau115@bu.edu<\/a>.<\/p>\n<p><strong>View BU Medical Campus <\/strong><a style=\"text-decoration: none;\" href=\"https:\/\/www.bumc.bu.edu\/about\/map-directions\/\">MAPS<\/a><\/p>\n<p><a style=\"text-decoration: none;\" href=\"https:\/\/www.bumc.bu.edu\/camed\/our-impact\/cores\/analytical-instrumentation-core\/\">\u25c4 Back to<\/a> <strong> Analytical Instrumentation Core<\/strong> <a style=\"text-decoration: none;\" href=\"https:\/\/www.bumc.bu.edu\/camed\/our-impact\/cores\/analytical-instrumentation-core\/\"> website<\/a>.<\/p>\n<p style=\"text-align: right;\"><a style=\"text-decoration: none;\" href=\"#top\">BACK TO TOP\u2191<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Savant ISS 100 Integrated SpeedVac System The Savant ISS 100 Integrated SpeedVac System is\u00a0compact, fully integrated systems designed specifically for DNA and RNA applications. The DNA-series SpeedVac vacuum concentrator delivers rapid and efficient concentration and drying of DNA\/RNA samples, nucleic acids, PCR preps and synthetic oligos. Our system is designed to accommodate micro centrifuge tubes. [&hellip;]<\/p>\n","protected":false},"author":10364,"featured_media":0,"parent":1312,"menu_order":22,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"bu-publication":[],"_links":{"self":[{"href":"https:\/\/www.bumc.bu.edu\/camed\/wp-json\/wp\/v2\/pages\/69557"}],"collection":[{"href":"https:\/\/www.bumc.bu.edu\/camed\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.bumc.bu.edu\/camed\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.bumc.bu.edu\/camed\/wp-json\/wp\/v2\/users\/10364"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bumc.bu.edu\/camed\/wp-json\/wp\/v2\/comments?post=69557"}],"version-history":[{"count":40,"href":"https:\/\/www.bumc.bu.edu\/camed\/wp-json\/wp\/v2\/pages\/69557\/revisions"}],"predecessor-version":[{"id":126981,"href":"https:\/\/www.bumc.bu.edu\/camed\/wp-json\/wp\/v2\/pages\/69557\/revisions\/126981"}],"up":[{"embeddable":true,"href":"https:\/\/www.bumc.bu.edu\/camed\/wp-json\/wp\/v2\/pages\/1312"}],"wp:attachment":[{"href":"https:\/\/www.bumc.bu.edu\/camed\/wp-json\/wp\/v2\/media?parent=69557"}],"wp:term":[{"taxonomy":"bu-publication","embeddable":true,"href":"https:\/\/www.bumc.bu.edu\/camed\/wp-json\/wp\/v2\/bu-publication?post=69557"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}